What to do if the wall-hung boiler refills too much water
As a common heating equipment in modern homes, wall-mounted boilers are inseparable from proper water pressure for their normal operation. However, many users may encounter the problem of excessive water replenishment during use, resulting in excessive water pressure and even safety hazards. This article will explain in detail the causes, solutions and preventive measures of excessive water replenishment in wall-mounted boilers, and provide relevant data reference.
1. Common causes of excessive water replenishment in wall-hung boilers

Excessive water replenishment is usually caused by improper user operation or unfamiliarity with water pressure standards. The following are common reasons:
| Reason | Description |
|---|---|
| Water pressure gauge misreading | The user did not read the water pressure gauge value correctly and mistakenly believed that the pressure was insufficient. |
| The water replenishment valve is not closed | After completing the water replenishment, you forget to close the valve, resulting in continuous water inflow. |
| Automatic water replenishment failure | Some wall-mounted boilers are equipped with an automatic water replenishment function, which may continuously replenish water if there is a malfunction. |
2. The dangers of excessive water replenishment in wall-hung boilers
Excessive hydration will cause excessive water pressure, which may cause the following problems:
| Hazard | influence |
|---|---|
| Safety valve pressure relief | When the water pressure is too high, the safety valve will automatically drain water, which may cause a waste of water resources. |
| Equipment damaged | Long-term high-pressure operation may damage pipes, water pumps and other components. |
| Decreased heating efficiency | Excessive water pressure may cause poor circulation in the system and affect the heating effect. |
3. Solutions to excessive water replenishment in wall-hung boilers
If you find that the wall-mounted boiler has too much water, you can take the following steps:
| steps | Operating Instructions |
|---|---|
| Close the water replenishment valve | Immediately close the water replenishment valve and stop further water inflow. |
| Drainage and pressure relief | Release part of the water through the radiator or drain valve to reduce the pressure to the normal range (1-1.5bar). |
| Check safety valve | If the safety valve has released pressure, check whether it has been reset or needs to be replaced. |
| Restart the boiler | After adjusting the water pressure, restart the device and observe whether it operates normally. |
4. How to prevent excessive water replenishment in wall-hung boilers
To avoid the problem of overhydration, users are advised to take the following precautions:
| measures | Description |
|---|---|
| Check water pressure regularly | Check the water pressure gauge once a week to ensure the pressure is between 1-1.5bar. |
| Standardize hydration operations | When replenishing water, slowly open the valve and observe the changes in the pressure gauge in real time. |
| Install pressure protection devices | A pressure sensor or automatic water cut-off device can be installed to prevent excessive pressure. |
| Read the manual | Read the manual of the wall-hung boiler carefully to familiarize yourself with the water replenishment process and precautions. |
5. Reference for the normal range of wall-hung boiler water pressure
Different brands and models of wall-mounted boilers have slightly different water pressure requirements. The following is the recommended water pressure range for common brands:
| brand | Normal water pressure range (bar) |
|---|---|
| power | 1.0-1.5 |
| Bosch | 1.2-1.8 |
| Rinnai | 1.0-1.5 |
| Ariston | 1.2-1.6 |
6. Professional maintenance suggestions
If the user repeatedly encounters the problem of excessive water replenishment or is unable to adjust the water pressure by himself, it is recommended to contact professional maintenance personnel. Here are the situations that may require professional repair:
| question | Processing method |
|---|---|
| Safety valve frequently releases pressure | Check or replace the safety valve. |
| Water replenishment valve cannot be closed | Repair or replace the fill valve. |
| The pressure gauge displays abnormally | Calibrate or replace pressure gauge. |
Through the above analysis and suggestions, users can better understand the correct method of replenishing water in wall-mounted boilers and avoid problems caused by improper operation. Proper maintenance of wall-mounted boilers can not only extend the life of the equipment, but also ensure the stable operation of the heating system.